MediaTek MT8781 octa-core, 2×Cortex-A76 @2.2GHz + 6×Cortex-A55 @2.0GHz; 8+128GB; 10.1 Inch IPS 1920×1200, 700cd/m² G+G 10-point glove touch; Android 13

The A10ST-EX is available in multiple hazardous-area configurations. Zone 1/21 and Zone 2/22 approvals are not interchangeable. Confirm the exact model, certificate number, Ex marking, ambient range and optional-module scope before ordering.

Battery: 10000mAh 3.8V non-removable

Camera: Front camera:5MP Rear camera:8MP

SEND US A MESSAGE

Just Email Us :

Address: Room 1303A,Building A,127 Chenshe Yishu Chanyeyuan,Minzhi Street, LongHua District,Shenzhen 518109

CONTACT INFORMATION

Address: Room 1303A,Building A,127 Chenshe Yishu Chanyeyuan,Minzhi Street, LongHua District,Shenzhen 518109

Reply Within 24hours for almost message!

Description

RUGGEDMASTER A10ST-EX Explosion-Proof Tablets

RUGGEDMASTER A10ST-EX Explosion-Proof Tablets supports wholesale and bulk order enquiries. Compare the standard specifications and optional modules for the configuration required by your project.

Ex Explosion-Proof Certificate

The A10ST-EX is available in multiple hazardous-area configurations. Zone 1/21 and Zone 2/22 approvals are not interchangeable. Confirm the exact model, certificate number, Ex marking, ambient range and optional-module scope before ordering.

IECEx CSAE 24.0031X — Ex ic IIC T4 Gc / Ex ic IIIC T135°C Dc;

ATEX CSANe 24ATEX1144X II 3GD (EU/UK valid);

ATEX II 2GD Ex ib IIC T5 Gb;

Ex ib IIIC T95°C Db (international);

Ex ib ⅡC T4 Gb (petrochemical);

Ex ib I Mb with MA/KA (coal & mining)

Certified Model: A10ST

Frequently Asked Questions about A10ST-EX Explosion Proof Tablet

1. What is the RUGGEDMASTER A10ST-EX?

It's the 10.1-inch Android member of our explosion-proof family: MT8781 octa-core, Android 13, 1920 × 1200 display, IP68, 4G LTE, with RJ45 and RS232 built in. Think of it as the inspection-and-forms workhorse — the Windows models exist for the software that won't run on Android.

2. Which hazardous-area zones can the A10ST-EX be used in?

Hazardous-area suitability depends on the exact ordered configuration and the certificate that covers it. The product page references documents and markings associated with Zone 1/21 and Zone 2/22 applications, but these scopes are not interchangeable.

3. Is the A10ST-EX ATEX certified?

The II 2GD configuration is backed by ECM technical-documentation verification (No. 6G250801.SCIQT68). For EU projects requiring ATEX, order the II 3GD configuration covered by CSANe 24ATEX1144X.

4. What does II 2GD Ex ib IIC T5 Gb / Ex ib IIIC T95°C Db mean?

This marking describes Group II equipment intended for gas and dust atmospheres using intrinsic safety level “ib.” IIC is the gas group, T5 is the gas temperature class, IIIC is the conductive-dust group, and T95°C is the maximum dust surface-temperature marking. Gb and Db are the equipment protection levels for Zone 1 gas and Zone 21 dust. Final suitability must still be checked against the exact certificate, equipment label and site classification.

5. Can the A10ST-EX be used in Zone 0 or Zone 20?

Not on the basis of a Gb/Db or Gc/Dc marking. Zone 0 and Zone 20 normally require higher equipment protection levels than the markings currently shown on this page.

6. Can the A10ST-EX be used in coal mines?

Only a configuration covered by valid Group I mining approval may be used for that application. A Group II gas-and-dust marking does not by itself cover underground coal mines.

7. What are the main hardware specifications?

MediaTek MT8781 octa-core processor, Android 13, 8GB RAM and 128GB storage, with an optional 12GB + 256GB configuration. It has a 10.1-inch 1920 × 1200 IPS display rated at 700 cd/m², ten-point glove touch and a stated surface hardness of at least 7H.

8. How rugged is the tablet?

IP68 ingress protection and MIL-STD-810H testing for drops up to 1.22 metres.

9. What is the battery capacity and expected runtime?

The built-in 10,000mAh battery is rated at ≥10 hours. Ask us for the test conditions behind that number if runtime drives your purchase — we'll quote the cycle, not just the figure.

10. Can the tablet be charged inside a hazardous area?

Treat it as no. Unless the certificate and user manual for your exact configuration say otherwise, charging happens outside the hazardous area — at the dock, in the truck, in the office. The optional external charging dock is a safe-area accessory.

11. What wireless connections and physical ports are available?

Wireless: 4G LTE, dual-band Wi-Fi 5, Bluetooth 5.2, and GPS/Galileo/GLONASS. Wired: RJ45 Ethernet, RS232, USB-C (OTG), USB-A, 3.5mm audio, 12-pin POGO dock, Micro SIM and a TF slot good for 256GB. If your project needs a port that isn't here, ask — the I/O set is fixed inside the certified configuration, so it has to be right at order time.

12. What is the operating temperature range?

−20°C to +60°C. If your site sees colder starts — outdoor winter work in northern regions, for example — tell us; the operating range is part of what the certificate covers.

RUGGEDMASTER A10ST-EX Explosion-Proof Tablets — performance and storage

Processor: MediaTek MT8781 octa-core, 2×Cortex-A76 @2.2GHz + 6×Cortex-A55 @2.0GHz, fanless passive cooling

System: Android 13

Storage: 8+128GB

RUGGEDMASTER A10ST-EX Explosion-Proof Tablets performance and storage

RUGGEDMASTER A10ST-EX Explosion-Proof Tablets — display and controls

Display: 10.1 Inch IPS 1920×1200, 700cd/m² G+G 10-point glove touch

Camera: Front camera:5MP Rear camera:8MP

RUGGEDMASTER A10ST-EX Explosion-Proof Tablets display and controls

RUGGEDMASTER A10ST-EX Explosion-Proof Tablets — connectivity and interfaces

Network: WiFi 5 dual-band, Bluetooth 5.2

Navigation positioning: GPS,Galileo,GLONASS

RUGGEDMASTER A10ST-EX Explosion-Proof Tablets connectivity and interfaces

RUGGEDMASTER A10ST-EX Explosion-Proof Tablets — power and protection

Battery: 10000mAh 3.8V non-removable

RUGGEDMASTER A10ST-EX Explosion-Proof Tablets power and protection

RUGGEDMASTER A10ST-EX Explosion-Proof Tablets technical specifications

Processor MediaTek MT8781 octa-core, 2×Cortex-A76 @2.2GHz + 6×Cortex-A55 @2.0GHz, fanless passive cooling
System Android 13
Storage 8+128GB
Display 10.1 Inch IPS 1920×1200, 700cd/m² G+G 10-point glove touch
NFC Support
Network WiFi 5 dual-band, Bluetooth 5.2
Battery 10000mAh 3.8V non-removable
Wall hole pitch / screw 154×71.5mm/ M3*4.5mm
Navigation positioning GPS,Galileo,GLONASS
Best-fit scenarios Zone 1 gas atmospheres in petrochemical and refinery units (IIC covers hydrogen and acetylene), Zone 21 combustible-dust areas, and coal/mining deployments under Ex ib I Mb with MA/KA certification.
I/O RJ45, Type-C (OTG), USB-A, 3.5mm jack, 12Pin POGO
ATEX ATEX II 2GD Ex ib IIC T5 Gb;
Card slot Micro SIM/TF up to 256GB
Protection IP68, MIL-STD-810H 1.22m drop, -20°C~60°C
Camera Front camera:5MP Rear camera:8MP
Light-sensitive Support
Product Configuration Certification Scheme or Document | Certificate / Document No. | Explosion-Protection Marking | Intended Application | Applicable Area
International Zone 2/22 Configuration IECEx Certificate of Conformity | IECEx CSAE 24.0031X | Ex ic IIC T4 Gc / Ex ic IIIC T135°C Dc | Oil and gas, chemical processing and industrial sites requiring IECEx documentation | IIC Gas Zone 2 / IIIC Dust Zone 22
European Zone 2/22 Configuration ATEX | CSANe 24ATEX1144X | II 3GD; complete Ex marking according to the certificate | EU and EEA hazardous-area projects; CE route currently recognized in Great Britain subject to applicable UK requirements | Gas Zone 2 / Dust Zone 22
II 2GD Technical-Verification Configuration ECM Voluntary Technical-Documentation Verification | 6G250801.SCIQT68 | II 2GD Ex ib IIC T5 Gb / Ex ib IIIC T95°C Db | Gas and conductive-dust applications requiring the stated technical marking | Marking associated with Gas Zone 1 / Dust Zone 21
Petrochemical Configuration National Ex Certification | CCRI 23.7672X | Ex ib IIC T4 Gb | Refineries, chemical plants, tank farms and other IIC gas environments | Gas Zone 1 / Zone 2, subject to the certificate
Coal and Mining Configuration MA/KA Mining Product Safety Approvals | KHC230065 | Ex ib I Mb | Underground coal mines and Group I mining applications | Mining Group I; not covered by Group II gas/dust approvals

Wholesale configuration enquiries

For bulk orders, specify the model, required operating system, memory and storage configuration, and any optional communication or data-capture modules. Optional features are configuration dependent. Use the Specs tab to check the full interface, power and environmental requirements.

Browse related explosion-proof tablets from RuggedMaster for your product comparison.

Processor MediaTek MT8781 octa-core, 2×Cortex-A76 @2.2GHz + 6×Cortex-A55 @2.0GHz, fanless passive cooling
System Android 13
Storage 8+128GB
Display 10.1 Inch IPS 1920×1200, 700cd/m² G+G 10-point glove touch
NFC Support
Network WiFi 5 dual-band, Bluetooth 5.2
Battery 10000mAh 3.8V non-removable
Wall hole pitch / screw 154x71.5mm/ M3*4.5mm
Navigation positioning GPS,Galileo,GLONASS
Best-fit scenarios Zone 1 gas atmospheres in petrochemical and refinery units (IIC covers hydrogen and acetylene), Zone 21 combustible-dust areas, and coal/mining deployments under Ex ib I Mb with MA/KA certification.
I/O RJ45, Type-C (OTG), USB-A, 3.5mm jack, 12Pin POGO
ATEX ATEX II 2GD Ex ib IIC T5 Gb;
Card slot Micro SIM/TF up to 256GB
Protection IP68, MIL-STD-810H 1.22m drop, -20°C~60°C
Camera Front camera:5MP Rear camera:8MP
Light-sensitive Support
Product Configuration Certification Scheme or Document | Certificate / Document No. | Explosion-Protection Marking | Intended Application | Applicable Area
International Zone 2/22 Configuration IECEx Certificate of Conformity | IECEx CSAE 24.0031X | Ex ic IIC T4 Gc / Ex ic IIIC T135°C Dc | Oil and gas, chemical processing and industrial sites requiring IECEx documentation | IIC Gas Zone 2 / IIIC Dust Zone 22
European Zone 2/22 Configuration ATEX | CSANe 24ATEX1144X | II 3GD; complete Ex marking according to the certificate | EU and EEA hazardous-area projects; CE route currently recognized in Great Britain subject to applicable UK requirements | Gas Zone 2 / Dust Zone 22
II 2GD Technical-Verification Configuration ECM Voluntary Technical-Documentation Verification | 6G250801.SCIQT68 | II 2GD Ex ib IIC T5 Gb / Ex ib IIIC T95°C Db | Gas and conductive-dust applications requiring the stated technical marking | Marking associated with Gas Zone 1 / Dust Zone 21
Petrochemical Configuration National Ex Certification | CCRI 23.7672X | Ex ib IIC T4 Gb | Refineries, chemical plants, tank farms and other IIC gas environments | Gas Zone 1 / Zone 2, subject to the certificate
Coal and Mining Configuration MA/KA Mining Product Safety Approvals | KHC230065 | Ex ib I Mb | Underground coal mines and Group I mining applications | Mining Group I; not covered by Group II gas/dust approvals

One-stop Solutation

RUGGEDMASTER offer End-to-End Solutions from Design to Production

Rich Experience

RUGGEDMASTER has more than 10 years of OEM and ODM manufacturing experience in customizing rugged tablets,rugged phones,rugged handhelds,rugged laptop,etc.

Strong R & D Capabilities

More than 10 years experienced R&D engineers provide mature custom solutions of outdoors products

Strict Quality Control

Including raw material test, online production test, PCS test, finished product test.

Competitive prices

RUGGEDMASTER offer competitive prices as we are able to produce our products efficiently and cost-effectively in our own factory.

view more >

Just Email Us :

Email : sales@ruggedmaster.com

Address: 4th Floor, A3 Building Yinlong Industry Base, Longdong Community, Longgang District,Shenzhen

Between 9:00 am-6: 00 pm from Monday to Friday Beijing time

We will reply you witin 12hours.

Can I buy from you online directly?

No, direct online purchase is not acceptable now as we want to give our partner more profits at their side

Can you send me a price list or no middleman quotation?

Yes,we can send it to your directly,please just email us and get our latest quotation directly.

Can you send me a catalog or brochure?

Yes,You can email us and we will send you our latest products catalogs to you

Do Your Company Accept Customizaion?

Yes,We accept OEM service. We have our own factory and excellent RD team, OEM is a part of our business, in addition, we offer ODM service, we would love to make good ideas happen.

What's the normaly lead time for OEM order?

Takes about 30 days for 500pcs OEM order after sample confirmed.

Do you sell refurbished or reconditioned devices?

Hello, no, we do not supply any refurbished or reconditioned devices or produucts, if you are interested in our night vision products, you can send your dealer or distributor request information

Do you sell your products to the military?

no, we do not supply the military because our products do not meet military standards and are intended only for civil purposes such as hunting, security, monitoring and other civil fields.

For the civil interest, the customers can send the dealer or distributor request information

0
Years Of Successful Business
0
Reviews Of 10000+ Satisfied Clients
0
Years Factory Warranty
0
Patents owned in global
0
Business Partners
0
Risk-Free Guarantee

WHY CHOOSE US? OUR ADVANTAGE

NEED BULK ORDER ?

WHOLESALE ENQUIRY